SOCT Copernicus REVO

Our supreme experience in Spectral Domain OCT allows us to provide the market with an updated SOCT Copernicus REVO featuring next generation spectrometer offering noticeablely faster scaning speed and enhanced image quality across the hole scanning window. The updated SOCT Copernicus REVO meets all demands in daily routine practice.

OCT made simple as never before. All you have to do is to position the patient and press the START button to acquire examinations of both eyes. The device will make examination independently. Small system footprint, various operator and patient positions allow to install SOCT Copernicus REVO even in the smallest examination rooms. Variety of review and analysis tools gives the operator a choice of using it as a screening or as an advanced diagnostic device. The noise reduction technology provides the finest details proven to be important for early disease detection.

Overview
New Model 80 000 A-scan/seconds  

The new REVO model with  80 000 A-scan/sec scanning speed reduce scan time and brings benefits for both clinicians and patients by reducing errors often caused by involuntary eye movements. Higher sensitivity spectrometer allows to visualize finer details.


RETINA
Single 3D Retina examination is enough to perform both Retina and Glaucoma analysis based on retinal scans. Software automatically recognizes 8 retina layers. Thusallowingamoreprecisediagnosisandmapping of any changes in the patient’s retina condition.



The SOCT Copernicus REVO 60 000 and 80 000 A-scan/seconds is available now with the Angiography module. 
OCT Angiography

This module allows visualization of the retinal microvasculature. Angiography SOCT is a non-invasive, dye-free technique providing 3D image of retinal blood circulation.
 
Software allows to observe, track and compare changes in the microvasculature of the retina in both eyes.
 
Standard Single View Detailed Single View
OCT Angiography Standard Single View	  OCT Angiography Detailed Single View
Both View  
OCT Angiography Both View  
Comparison View Progression View
OCT Angiography Comparison View OCT Angiography Progression View

QUANTYFICATION TOOLS: FAZ, VFA
FAZ – Foveal Avascular Zone measurements allow to quantify and monitor changes in Superficial and Deep vascular layer.  FAZ tool is also available for narrow and wide scans.
OCT Angiography FAZ – Foveal Avascular Zone   OCT Angiography FAZ – Foveal Avascular Zone
  Area [mm2]: 0,48

VFA – Vascular Flow Area allows to examine the pathologically affected area and precisely measure the area covered by vascu-larization. User can easily measure area on predefined or own selected vascular layer.
OCT Angiography VFA – Vascular Flow Area  OCT Angiography VFA – Vascular Flow Area
  Area [mm2]: 13,45
Flow area [mm2]:   2,85

ANGIO MOSAIC
The Angiography mosaic delivers high-detailed images over large field of the retina. Advanced tab provides: view of any vascular layers, enface view of vascular layers, depth coded and thickness map.

Mosaic modes: 10x6 mm
 
Manual (up to 12 images)


GLAUCOMA
Comprehensive glaucoma analytical tools for quantification of the Nerve Fiber Layer, Ganglion layer and Optic Head with DDLS allow for the precise diagnosis and monitoring of glaucoma over time.
With the golden standard 14 optic nerve parameters and a new Rim to Disc and Rim Absence the description of ONH condition is quick and precise.
Advanced view which provides combined information from Retina and Disc scan to integrate details of the Ganglion cells, RNFL, ONH in a wide field perspective for comprehensive analysis.

Advance Retina & ONH

ONH Single
GLAUCOMA Advance Retina & ONH  GLAUCOMA ONH Single

Asymmetry Analysis of Ganglion layers between hemi-spheres and between eyes allows easier identification and detection of glaucoma in early stages and in non-typical patients.

Ganglion Both

Ganglion Progression
GLAUCOMA Ganglion Both  GLAUCOMA Ganglion Progression

Implemented the DDLS  - Disc Damage Likelihood Scale which use 3 separate classification for small, average and large discs. It supports the practitioners in a quick and precise evaluation of the patient’s glaucomatous disc damages.

ONH Both

ONH Progression
GLAUCOMA ONH Both  GLAUCOMA ONH Progression

COMPLET YOUR GLAUCOMA REPORT
To eliminate common problem with the understanding of the patient’s IOP pachymetry module provides IOP Correction value.  With the implemented Adjusted IOP formula you can quickly and precisely understand the measured IOP value.  
As the Pachymetry and Anterior Chamber Angle Verification require no additional attachments, the predefined Glaucoma protocol, which consists of Retina, Disc and Anterior scans, can be done automatically to reduce patient chair time.

Closing angle

Anterior single view
Closing angle  Anterior single view
  * Images courtesy of Prof. Edward Wylęgała MD, PhD

ANTERIOR
For standard examination no additional lens is required. Additional adapter provided with the device allows to make wide scans of anterior segment.

Cornea single 

Cornea both
ANTERIOR Cornea single   ANTERIOR Cornea both
Cornea Comparison Cornea Progression
Anterior Cornea Comparison Anterior Cornea Progression


BIOMETRY OCT is optional software module to purchase for REVO model with 27 000, 60 000 nad 80 000 A-scan/sec scanning speed
B-OCT™ innovative method of using the  posterior OCT device to measure ocular structure along eye axis .
OCT Biometry provides complete set of Biometry parameters: Axial Length AL, Central Cornea Thickness CCT, Anterior Chamber Depth ACD, Lens Thickness LT.

Result review
 
Analysis window
 
Visually verify your measurement
All measurement calipers are shown on the all boundaries OCT image provided by REVO. It allows to can visually verify and correct what structure of the eye has been measured.


TOPOGRAPHY OCT is optional software module to purchase
T-OCT™ is a pioneering way to provide detailed corneal Curvature maps by using posterior dedicated OCT. Ante-rior, Posterior  surface and Corneal Thickness allow to provide the  True Net Curvature information. With Net power, the precise understading of the patient’s corneal condition comes easily and is free of errors associated with modelling of posterior surface of the cornea.  SOCT T-OCT module provides Axial maps, Tangential maps, Total Power map, Height maps, Epithelium and Corneal thickness maps.
Corneal topography module clearly shows the changes in the cornea on the difference map view. Customize your
Topography module provides:
  • Full featured Corneal mapping of Anterior, Posterior and Real
  • Precise Astigmatism Display Option (SimK: Anterior, Posterior, Real,  Meridian and Emi-Meridian ø 3, 5, 7 mm zones
KERATOCONUS SCREENING
Easly detect and classified keratoconus with Keratoconus classifier. Classification based on KPI, SAI, DSI, OSI and CSI. In the early stages of kera-toconus the results can be complemented by Epithelium and Pachymatery maps.
Normal Astigmatysm Keratoconus
KERATOCONUS SCREENING  KERATOCONUS SCREENING  KERATOCONUS SCREENING

COMPARE THE EXAMS
Comprehensive software features  a range of selectable views: Single, Both. See details on standard Singe view and easly see corneal asymmetry on the Both view.
The follow-up feature in to the T-OCT™ module, allows fully compare the changes in the corneal topography over time for:
  • LASIK undergone patients
  • Keratoconus patients
  • The contact lens wearers
Single Both
TOPOGRAPHY OCT SINGLE  TOPOGRAPHY OCT BOTH
Comparison Progression
TOPOGRAPHY OCT COMPARISON TOPOGRAPHY OCT PROGRESSION


FOLLOW UP
High density of standard 3D scan allows to precisely track the disease progression. Operator can analyze changes is morphology, quantified progression maps and evaluate the progression trends.
 
Progression Morphology  Progression Quantification
FOLLOW UP Progression Morphology	  FOLLOW UP Progression Quantification


COMPARISON
Comparison view allows in easy and convince way to review results from two visits. The view is available for most of the scan programs. 


NETWORKING

A proficient networking solution increases productivity and an enhanced patient experience. It allows you to view and manage multiple examinations from review stations in your practice. Effortlessly helping to facilitate patient education by allowing you to interactively show examination results to patients. Every practice will have different requirements which we can provide by tailoring a bespoke service. There is no additional charge for the server module.

DICOM
Store, exchange, and transmit results through DICOM gateway to the hospital network. 

ENHANCE TOMOGRAMS - 2 µm Ultra High (Digital) Resolution
ENHANCE TOMOGRAMS - 2 µm Ultra High (Digital) Resolution

CHOROID VISUALIZATION


CLINICAL IMAGES






CORNEA SCAN


Wide cornea scan, Descemet’s membrane detachment (DMD) and iridocorneal adhesions
Wide cornea scan, Descemet’s membrane detachment (DMD) and iridocorneal adhesions
* Images courtesy of Prof. Edward Wylęgała MD, PhD

BACK OF THE CRYSTALLINE LENS


WIDE SCAN WITH LENS DEFECT


CONTACT LENS ON THE CORNEA


CONTACT LENS ON THE CORNEA AND THE SCLERA


ANTERIOR WIDE

Angle to Angle scan, narrow angles
Angle to Angle scan, narrow angles
*Image courtesy of Bartosz L. Sikorski MD, PhD

WIDE RETINA SCAN


PERIPHERAL SCAN


 
Tech specs
Technology
Spectral Domain OCT
Scanning speed 80 000 / 60 000 / 27 000 measurements per second
80 000 and 60 000 A-scan/sec sanning speed is an optional hardware feature and has to be selected when ordering
Light Source
SLED, Wavelength 830 nm
Bandwidth
50 nm half bandwidth
Axial resolution
5 μm in tissue
Transverse Resolution
12 μm, typical 18 μm
Overall scan depth
2.4 mm
Scan range
Posterior 5–12 mm, Anterior 3–16 mm
Scan program 3D, Radial, B-scan, Raster, Cross
Fundus image
Live Fundus Reconstruction
Alignment method
Fully automatic, Automatic
Retina analysis
Retina thickness, Inner retinal thickness, Outer retinal thickness,
RNFL+GCL+IPL thickness, GCL+IPL thickness, RNFL thickness,
RPE deformation, IS/OS thickness
Angiography OCT
available only for SOCT Copernicus REVO with 80 000 and 60 000 measurements per second
Angiography mosaic
 
Superficial plexus, Deep Plexus, Outer Retina, Choriocapilaries,
Depth Coded, Custom, Enface, Thickness map
Acquistion method: Auto, Manual

Mosaic modes: 10x6 mm, manual up to 12 images
Glaucoma analysis
RNFL, ONH morphology, DDLS, Ganglion analysis as RNFL+GCL+IP
and GCL+IPL, OU and Hemisphere asymmetry 
Anterior
Pachymetry map, Epithelium map, LASIK flap assesment,
Angle Assessment, AIOP, AOD 500/750, TISA 500/750
Anterior Wide Scan
Angle to Angle view (Adapter required)
Biometry OCT
an optional software module to purchase
AL, CCT, ACD, LT
Corneal Topography Map
an optional software module to purchase for SOCT Copernicus REVO with 80 000 and 60 000 measurements per second
Axial [Anterior, Posterior], Refractive Power [Kerato, Anterior, Posterior, Total], Net Map, Axial True Net, Equivalent Keratometer, Elevation [Anterior, Posterior], Height
Connectivity DICOM Storage SCU, DICOM MWL SCU, CMDL, Networking
Minimum pupil size
3 mm
Focus adjustment range
-25 D to +25 D
Dimensions (W×D×H)
382 × 556 × 469 mm
Weight
23 kg
Fixation target
OLED display (The target shape and position can be changed),
External fixation arm
Power supply
100–240 V, 60/50 Hz
Power consumption
115–140 VA

 
Find your Distributor